We've collected a number of photos from jobs we've been a part of over the years. Take a look at our galleries to see good and poor examples of the building envelope.
Prosoco CAT 5 Sunset Beach Condos
Recladding of Condo Units after failure. Â Units are less than 5 years old
New Cat 5 Air Barrier which tolerates rain immediately after installation.
Waterfront location.
Recladding of Condo Units after failure. Â Units are less than 5 years old
Prosoco FastFlash Wake Forest University
Window Replacement and Renovation projects at WFU
Future Aim Dam opportunity to seal inside openings.
Training contractors at start up.
Window Replacement and Renovation projects at WFU
Prosoco CAT 5 Office Bldg Reclad Raleigh, NC
Office Building in Raleigh, NC where owner is re-cladding.
Cat 5 installation during cold weather and rain season.
Field inspection discovered missing wall-roof tie-in. This is the most critical and often missed detail in our industry.
Office Building in Raleigh, NC where owner is re-cladding.
R-Guard Fast Flash
Properly flashing in building wrap with Prosoco Fast Flash or Air Dam.
Properly flashing in building wrap with Prosoco Fast Flash or Air Dam.
Prosoco Siloxane WB App State
Rilem Tube testing
Rilem Tube testing
Prosoco Siloxane WB used at App State
Rilem Tube testing
Poor Job Details
Poor Job Building-Wrap Mock Up
Building wrap is mostly done wrong.
This is often the finished detail.
All parties need to understand proper waterproofing details to get the mock up done right.
Building wrap is mostly done wrong.
Poor Job Coastal Elementary School
Many air barrier systems require protection of the wall.
Moisture can cause failures after successful application.
Repairs are costly for all involved, get it done right the first time.
Many air barrier systems require protection of the wall.
Poor Job NC CMU School
Elastomeric membranes require protection of walls for entire project, failure to do so lead to many failures. STPE membranes do not.
Elastomeric membranes and Synthetic Permeable membranes can often re-emulsify if left unprotected. STPE membranes do not.
This was first detected where membrane was leaking our the weeps.
Elastomeric membranes require protection of walls for entire project, failure to do so lead to many failures. STPE membranes do not.
Miscellaneous Jobs
Penetrations not properly flashing with Peel-N-Stick. Liquid Flashing easier to install correctly.
This does not meet Continuous Insulation Building Code Requirements.
Proper sequencing can ensure a watertight installation.
Penetrations not properly flashing with Peel-N-Stick. Liquid Flashing easier to install correctly.